IJTEEE

Open Access Journal of Scientific, Technology & Engineering Research


International Journal of Technology Enhancements and Emerging Engineering Research (ISSN 2347-4289)
QUICK LINKS
CURRENT PUBLICATIONS



IJTEEE >> Volume 2 - Issue 8, August 2014 Edition



International Journal of Technology Enhancements and Emerging Engineering Research  
International Journal of Technology Enhancements and Emerging Engineering Research

Website: http://www.ijteee.org

ISSN 2347-4289



Harmonic Reduction For Non-Linear Loads Using Stationary Reference Frame Theory

[Full Text]

 

AUTHOR(S)

T. Paulraj, M. Arun Prakash.

 

KEYWORDS

Keywords: non-linear load; current harmonics; instantaneous reactive power theory; sinusoidal current.

 

ABSTRACT

ABSTRACT: Prominent harmonics in IT offices are essentially due to the presence of SMPS in computers large numbers. In a three-phase, four-wire system, current harmonics leads to flow zero sequence current in neutral conductor, increased losses in motors, false tripping of circuit breakers. In this paper, VSI is designed as a compensator based instantaneous reactive power theory. And is used to mitigate the current harmonic caused by 6 pulse diode rectifier is mitigated. Simulation is done with MATlab software and results are verified.

 

REFERENCES

[1]. M. Brenna, R. Faranda, and E. Tironi, “A new proposal for power quality and custom power improvement: OPEN UPQC,” IEEE Transactions onPower Delivery, vol. 24, no. 4, pp. 2107 –2116, Oct. 2009.

[2]. P. Salmeron and S. Litran, “Improvement of the electric power qualityusing series active and shunt passive filters,” IEEE Transactions onPower Delivery, vol. 25, no. 2, pp. 1058 –1067, April 2010.

[3]. S. Srikanthan and M. Mishra, “Constant frequency current control usinga ramp comparison method for a Current unbalance compensator application,” in TENCON2008 - IEEE Region 10 Conference, pp. 1-6, Nov. 2008.

[4]. B. Singh, P. Jayaprakash, and D. Kothari, “A T-connected transformerand three-leg VSC based CURRENT UNBALANCE COMPENSATOR for power quality improvement,”IEEE Transactions on Power Electronics, vol. 23, no. 6, pp. 2710 –2718,Nov. 2008.

[5]. M. Saeedifard, H. Nikkhajoei, and R. Iravani, “A space vector modulatedstatcom based on a three-level neutral point clamped converter,” IEEETransactions on Power Delivery, vol. 22, no. 2, pp. 1029 –1039, April2007.

[6]. F. Blaabjerg, R. Teodorescu, M. Liserre, and A. Timbus, “Overviewof control and grid synchronization for distributed power generationsystems,” IEEE Transactions on Industrial Electronics, vol. 53, no. 5,pp. 1398 –1409, Oct. 2006.

[7]. Janko, N., R. Cajhen, M. Seliger and P. Jereb, 1994. Active power filter for non-linear a.c loads. IEEE Trans. on Power Electronics, 9: 92-96. [8] ArindamGhosh, Gerard Ledwich, “Power Quality Enhancement Using Custom Power devices”, August 2002, ISBN 1- 4020 – 7180-9, Book published by Kluwer Academic Press.

[8]. Peng, F. Z.: “Harmonic Sources and Filtering Approaches,” IEEE IA Magazine, July/August 2001, 18–25.

[9]. Akagi, H and H. Fujita, 1995. A new power line conditioner for harmonic compensation in power systems. IEEE Trans. on Power Delivery, 10: 1570-1575..