Performance Evaluation Of Gas Turbine By Reducing The Inlet Air Temperature

[Full Text]

 

AUTHOR(S)

V. Gopinath1, G. Navaneethakrishnan2

 

KEYWORDS

Keywords : Gas turbine, evaporative coolers, vapor compression chillers, absorption chiller

 

ABSTRACT

ABSTRACT: Performance of a gas turbine is mainly depends on the inlet air temperature. The power output of a gas turbine depends on the mass flow rate of air. Now days the atmosphere temperature is hot, so the air is less density, the mass flow rate will reduce and automatically the power output will reduce. A reduce of 1°C temperature of inlet air increases the power output by approximately 0.7MW. To reduce the inlet air temperature by using the various techniques evaporative coolers, vapor compression chillers, and absorption chillers. In this paper the performance of 100MW model capacity gas turbine is compared by reducing the inlet air temperature from 35°C to 25°C. The results are taken from the GT PRO software and this software is mainly used for power plant design.

 

REFERENCES

[1] Thamir K. Ibrahim, M. M. Rahman, “Improvement of gas turbine performance based on inlet air cooling systems: A technical review”, IJPS, 2011, Vol. 6(4), pp. 620-627. (references)

[2] Ait-Ali MA , “Optimum power boosting of gas turbine cycles with compressor inlet air refrigeration” ASME., 1997, 119: 124-130.

[3] Boonnasaa S, Namprakaia P, Muangnapoh T, “Performance improvement of the combined cycle power plant by intake air cooling using an absorption chiller” Ener.,2006, 31: 2036-2046.

[4] Hosseini R, Beshkani A, Soltani M, “Performance improvement of gas turbines of Fars (Iran) combined cycle power plant by intake air cooling using a media evaporative cooler” Ener. Conver. Manage., 2007, 48: 1055-1064.

[5] Kakaras E, Doukelis A, Karellas S, “Compressor intake-air cooling in gas turbine plants. Energy”, 2004, 29: 2347-2358.

[6] Kakaras E, Doukelis A, Prelipceanu A, Karellas S, “Inlet air cooling methods for gas turbine based power plants” Trans. ASME., 2006, 128: 312-317.

[7] Polyzakis AL, Koroneos C, Xydis G, “Optimum gas turbine cycle for combined cycle power plant” Ener. Conver. Manage., 2008, 49: 551- 563.

[8] Sadrameli SM, Goswami DY, “ Optimum operating conditions for a combined power and cooling thermodynamic cycle”, Appl. Ener., 2007, 84: 254-265.

[9] Zadpoor AA, Golshan AH, “Performance improvement of a gas turbine cycle by using a desiccant-based evaporative cooling system” Ener., 2006, 31: 2652-2664.

[10] Mohanty B, Paloso J, : Enhancing gas turbine performance by intake air cooling using an absorption chiller” Heat Recovery Syst CHPJ 1995; 15(1):41–50.