Calibration Of Waterloss Impacts On Water Distribution And Accessibility In Akure, Nigeria

[Full Text]

 

AUTHOR(S)

Olotu Yahaya, Alimi L. O, Rodiya. A.A, Omotayo F.S

 

KEYWORDS

Keywords: Water, NRW, Simulation, Distribution, Resources, Public, Cost

 

ABSTRACT

Abstract: Safe drinking water is a necessity for life. Providing quality drinking water is a critical service that generates revenues for water utilities to sustain their operations. Population growth put an additional strain on the limited resources. The annual volume of water lost is an important indicator of water distribution efficiency, both in individual years, and as a trend over a period of years. Application of deterministic simulation model on public water supply variables reveals the volume of non-revenue water (NRW) and its cost effects have further created a complex system for the availability, distribution and affordability of the utility. Gradual annual increase in public water supply (AWS) from 9.0 *106m3 to 14.4 * 106m3 had negative effect on annual water accessed(AWA) with R2 = 0.096; and highly significant with annual water loss (AWL) with R2 = 0.99. This development indicates that water loss mainly through leakages and bursts is a function of public water supply. Hence, estimated volume and cost annual revenue water (NRW) in Akure is 6 million m3 and 15.6 million USD respectively. Critical analysis shows that the lost annual revenue could be used to provide education and health services for a period of 6-month in the region.

 

REFERENCES

[1]. Besner, M.-C. and A. Camper. 2002. Explaining the occurrence of coliforms in distribution systems. Jour. AWWA 94(8):95-109.

[2]. Bonds, C and Richard W., P.E. 1997. Stray current effects on ductile iron pipe. Birmingham, AL: Ductile Iron Pipe Research Association.

[3]. Butler, D (2009): 'Leakage Detection and Management', Palmer Environmental

[4]. Fanner, (2007): ‘Leakage Management Technologies’, AWWARF Project Report 2928

[5]. Lambert A, Brown TG, Takizawa M, Weimer D.,1999. A review of performance indicators for real losses from water supply systems. AQUA., Dec 1999. ISSN 0003-7214

[6]. May, A (2005) “International Benchmarking of Leakage from Water Reticulation Systems”, Proceedings of Leakage 2005 Conference, 2005

[7]. Mckenzie, RS, 1999. Development of a standardised approach to evaluate burst and background losses in potable water distribution systems : SANFLOW User Guide. South African Water Research Commission, Report TT 109/99, ISBN 1-86845-490-8.

[8]. RMP, 2003 Guide on Road Map to Ondo-State Development